User Access Via the Keypad
87
Siemens Building Technologies
Fire Safety & Security Products
09.2008
11.3 Setting the System: PARTSET B
The PARTSET B option provides the following functionality:
z
Perimeter protection to a building while allowing
free movement through the exit and access
areas
z
Exclusion of EXCLUDE B zones from protection
z
Instant activation of alarm on selection of mode;
by default there are no exit times associated with
PARTSET B
To select PARTSET B, enter a valid user code, scroll to the PARTSET B option
and press SELECT (right soft key).
NOTE
Partset A and Partset B configuration modes are dependent upon how the system has been
programmed.
11.4 Failing to Set the System
The system fails to set if there is an open or fault condition detected on an alarm
zone when the FULLSET or PARTSET A/B option
is selected. The Keypad displays the zone number
and description.
To set the system, locate the zone and close or fix
the fault. Repeat the FULLSET or PARTSET A/B operation.
11.5 Force Setting the System
The system can be forced to set while an alarm
zone is still open. This operation inhibits the open
zone and sets the system as normal.
If a user has the right to FORCE SET the system
and an alarm zone is open, when the FULLSET or
PARTSET option is selected, the Keypad buzzer
beeps and the first line of the display indicates the
open zone. The user is presented with the options
to QUIT (left soft key) or FORCE (right soft key).
QUIT: Selecting this option aborts the attempt to
set the system and returns the user to User Programming.
FORCE: Selecting this option inhibits the open zone and forces the system to set.
...PARTSET B?...
EXIT
SELECT
18/07/2008 12:55
PARTSET B SET
ZONE 1
QUIT
OPEN
...FORCED SET?...
BACK
SELECT
18/07/2008 12:30
SETTING 45 SECONDS
18/07/2008 12:30
SYSTEM FULLSET