Communication with SIMATIC S7-1200
11.1 Integration in SIMATIC S7-1200
SIWAREX WP251
192
Manual, 12/2015, A5E37203357A
Parameter (read)
Meaning
TECHNOLOGICAL_ERR
ORS_1
Technology error word 1 according to the "Messages" section
TECHNOLOGICAL_ERR
ORS_2
Technology error word 2 according to the "Messages" section
DATA_CMD_ERRORS_1 Data/command error word 1 according to the "Messages" section
DATA_CMD_ERRORS_2 Data/command error word 2 according to the "Messages" section
DATA_CMD_ERROR_AD
D_INFO
Additional information for data/command errors according to the "Messages" section
Parameter (write)
Meaning
PRESET_TARE_VALUE Preset tare value (can be used via command 1016 or with corresponding "Dosing start option"
(DR 25) for taring)
AQ_CONTROL
Control value for the analog output (the output must be configured accordingly for this in DR 7)
DQ_CONTROL
Control bits for the four digital outputs (the outputs must be configured accordingly for this in
DR 7)
TRANSITIONS
Blocking conditions for weighing steps 0-7. For example, if the "TRANSITION_STEP_2" bit is
set and a weighing is started, WP251 stops the weighing cycle after performing weighing step
1 and sets the "Step blocked (transition)" bit in the AWI Status. The weighing or weighing step
2 is not continued until the "TRANSITION_STEP_2" bit is reset.
SECURE_DISPLAY_CON
TROL
Parameter for communication of the calibratable "SecureDisplay" display with the SIWAREX
WP251 module. The "SecureDisplay" communication block is interconnected with this pa-
rameter for scales requiring official calibration.
11.1.6
Error codes of function block
Table 11- 2 Statuses/errors when working with the function block
Error bit
Error description
bo_ApplIDError
Address module does not match the function block
bo_ApplIDDRError
Data record does not match the inserted module
bo_SFBError
Runtime error during transmission of data record
bo_RdPerError
Reading of I/O data failed
bo_LifeBitError
SIWAREX no longer responds
bo_StartUpError
Command was sent although StartUp is still TRUE
bo_WrongFW
Data record version does not match the firmware
bo_InvalidCMD
An invalid command code was sent
bo_DataOperationError
Synchronous data operation error has occurred
bo_StartUp
Startup synchronization of module running
Summary of Contents for SIWAREX WP251
Page 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Page 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Page 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...