![Siemens SIWAREX WP251 Manual Download Page 183](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538183.webp)
Command lists
10.2 Command lists
SIWAREX WP251
Manual, 12/2015, A5E37203357A
183
Table 10- 5 Scale commands
Command
code
Command
Description
Protected
1001
Zero
Set to zero (semi-automatic)
1011
Tare
Taring (semi-automatic)
1012
Delete Tare
Delete current tare weight
1013
Activate Preset Tare 1
Preset tare weight value from DR 15 is transferred
1016
Activate Preset Tare S7
Preset tare weight value from SIMATIC I/O interface
(see section I/O interface of function block
(Page 191)) is transferred.
Table 10- 6 Scale commands
Command
code
Command
Description
Protected
1101
Start single
weighing
Starts an individual dosing cycle.
1103
Start continuous
mode
Starts n dosing cycles in continuous succession Continuous operation
ends automatically if a total set point (DR 21) was specified and reached
or alternatively using the "Stop continuous mode (1123)" command. If a
dosing cycle is still active, it is completed. The "Abort weighing (1124)"
command also ends continuous operation but does not terminate an
active dosing cycle.
The "Continuous mode active" bit in the AWI Status (DR 30) indicates
whether or not WP251 is operating in continuous mode.
1121
Stop weighing
Current dosing cycle is stopped and the "Weighing cycle stopped" bit is
set in the AWI Status (DR 30). The "Continue weighing (1141)" command
can be used to continue and thus complete the cycle from this status.
1122
Activate check
stop
If check stop points have been defined (see section I/O interface of func-
tion block (Page 191)), these are activated by "Activate check stop" and
the dosing cycle stops at the predefined points.
1123
Stop continuous
mode
Continuous operation is stopped. If the command is issued within a dos-
ing cycle, this dosing cycle is first finished and WP251 then waits in
weighing step 0. The "Continuous mode active" bit in the AWI Status (DR
30) is reset.
1124
Abort weighing
The current dosing cycle is directly aborted and WP251 jumps immedi-
ately to weighing step 0.
1125
Rest weighing
The command can be issued within the dosing cycle or outside of it
(=weighing step 0). Any active coarse or fine signal is directly reset, a
tolerance check is performed, a log print is created and – if configured in
DR 25 –the scale is emptied. WP251 then waits in weighing step 0.
1126
Manual emptying
ON
The command can be issued only in weighing step 0. The "Emptying
signal" bit is then set to TRUE and a linked digital output, if any, is set.
The command is used to clean the scale or to open it manually for ser-
vice.
Summary of Contents for SIWAREX WP251
Page 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Page 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Page 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...