RN-S SA
Operating Instructions, 09/2016, A5E32605810A-03
47
Technical data
7
7.1
Stainless steel compact installation units
Table 7- 1
Technical specifications of the stainless steel compact installation units
Size
Value at rated load
60 kg to 280 kg
0.5 t / 1 t
2 t to 5 t
10 t / 13 t
Max. lateral deflection with load cell
± 2 mm
± 3 mm
± 3 mm
± 3 mm
Lifting path of the top plate
2 mm
3 mm
3 mm
3 mm
Restoring force per millimeter of lateral
deflection of top plate
1)
5.6% per mm
3.7% per mm
3.7% per mm
3.2% per mm
Permitted transverse force on the top
plate with lowered top plate
0.5 kN
0.7 kN
1.5 kN
5 kN
Permitted supporting load with fixed top
plate
20 kN
30 kN
55 kN
85 kN
Permitted lifting force on the top plate
2.4 kN
4.2 kN
9.4 kN
16 kN
Permitted transverse force on the top
plate with fixed top plate
3 kN
3 kN
9 kN
14 kN
Cross-section of grounding cable
10 mm
2
10 mm
2
10 mm
2
16 mm
2
1)
Specification in % of applied load with load cell
7.2
Stainless steel guide elements
Table 7- 2
Technical specifications of the stainless steel compact guide elements
Size
Value at rated load
60 kg to 280 kg
0.5 t / 1 t
2 t to 5 t
10 t / 13 t
Permissible transverse force
1)
1.5 kN
2.5 kN
5 kN
10 kN
1) The values apply to one guide element.
Summary of Contents for SIWAREX WL280
Page 20: ...Description 3 2 Design and function RN S SA 20 Operating Instructions 09 2016 A5E32605810A 03 ...
Page 44: ...Mounting 5 4 Dismantling RN S SA 44 Operating Instructions 09 2016 A5E32605810A 03 ...
Page 56: ...Appendix A 1 Technical support RN S SA 56 Operating Instructions 09 2016 A5E32605810A 03 ...