5 Weighing functions
5.1 General information
All parameters are set with default values from the manufacturer. With the
command "Load factory setting", the ex-factory parameter settings can be restored.
With the two-channel SIWAREX U, this command affects both channels.
The default parameters are set so that the scale is immediately ready for operation.
It is not necessary to re-enter all parameters. The advantage of this solution is that
you yourself can determine to what extent the default values are to be kept and the
degree to which the behavior of the scale should be adapted to the application.
All parameters are divided into data records (DR). The data records are organized
according to work steps (tasks) which you must carry out during commissioning or
during the process itself.
In the following parameter description, the weighing functions affected by the
parameters are described at the same time.
The parameters of a data record are shown in a table to start with. This is then
followed by the precise parameter description for the parameters of this data set.
After receiving new parameters, SIWAREX U runs a plausibility test. If a parameter
error occurs, the data set will not be accepted by SIWAREX U (not saved) and a
"synchronous" message is output (see Chapter
5.2 DR3 adjustment parameters Channel 1, DR 4 adjustment
parameters Channel 2
The adjustment parameters must be checked for each scale and changed where
necessary. With a single-channel SIWAREX U there is only DR3; with a two-
channel SIWAREX U the adjustment parameters for channel 2 are stored in DR4.
The scale is basically defined by the adjustment parameters and adjustment
execution.
Procedure:
o
Check all parameters and modify as necessary.
o
Send DR3 (DR4) to the scale.
o
Carry out the adjustment of the scale.
o
Receive DR3 (DR4) from the scale.