11.9 Mechanical Requirements and Data
Testing
Standards
Test values
Vibration
in operation
IEC 60068-2-6
Test Fc
Switching cabinet installation:
0.30 mm from 10 to 57 Hz; 2 G from 57 to
150 Hz
Top-hat rail mount:
15 mm from 10 to 57 Hz; 1 G from 57 to
150 Hz
10 deflections per axis, 1 Octave/Minute
Shock
in operation
IEC 60068-2-27
Test Ea
150 m/s
2
, Half sinus
Duration: 11 ms
Number: 3 per axis each
in neg. and pos. direction
Free fall
IEC 68000-2-32
Test Ed
Fall height 1m, 5 times in shipping
packaging
Tipping over
IEC 68000-2-32
100 mm, four times without packaging
Table 11-9
Data: Mechanical requirements
11.10 Electrical-, EMC- and Climatic Requirements
11.10.1 Electrical Protection and Safety Requirements
Note:
The licenses that are currently valid for SIWAREX MS are indicated on the SIWAREX MS rating
plate.