Weighing
Functions
Name
Type
Length
Default
Range of Values / Meaning
Checksum WORD
2
0
Checksum
BYTE
1
0
Reserved
Preset tare
BYTE
1
0
1 = Tare memory contains ext. default value
Tare process value *100 DINT
4
0
Tare weight * 100
Zero set value *100
DINT
4
0
Zero set value * 100 (set during zero setting)
12
Table 5-5
Allocation of DS 26
5.7 DS 30 Process Values
The current states and data in the scale can be monitored using process values.
Name
Type
Length
Default
Range of Values / Meaning
Checksum
WORD
2
---
Checksum CRC16
Scale status
WORD 2 --- Scale
status
For description see chapter
Operating error bits
BYTE
1
---
Operating error bits
For description see chapter
Reserved
BYTE 1 0 Reserve
1
Gross process value
INT 2
---
Gross
weight
For description see chapter
Net process value
INT 2
---
Net
weight
For description see chapter
Tare process value
INT 2
---
Tare
weight
For description see chapter
G/N weight
INT
2
---
B/N weight value to display
For description see chapter
G/N weight *10
DINT
4
---
B/N weight value with 10x resolution (basis for ASCII weight
value)
For description see chapter
Tare weight
INT
2
---
Tare weight value
For description see chapter
Unfiltered raw value
WORD
2
---
Unfiltered digital value from ADU
For description see chapter
Filtered raw value
WORD
2
---
Filtered digital value
For description see chapter
Weight value ASCII
STRING[14]
16
---
ASCII weight value (at an increased resolution for a short time
after the command)
For description see chapter
Millisecond
INT
2
0
Runtime – Milliseconds (0....999)
For description see chapter
Second
BYTE
1
0
Runtime – Seconds (0...59)
Minute
BYTE
1
0
Runtime – Minutes (0...59)
Hour
INT
2
0
Runtime – Hours (0...32000)
46
Table 5-6
Allocation of DS 30
SIWAREX MS 5-31