Name
Type
Address Range of Values / Meaning
Reference
Conti-Status flags
DINT
DBD004
Status bits (see below)
Gross process value
REAL
DBD008
Gross weight
Net process value
REAL
DBD012
Net weight
Tare process value
REAL
DBD016
Tare weight
G/N weight
REAL DBD020
Verifiable B/N weight value for display and
logging purposes (Basis for DR ASCII weight
value)
B/N weight_x10
REAL DBD024
Verifiable B/N weight value with 10 fold
resolution (Basis for DR ASCII weight value)
Tare weight
REAL DBD028
Verifiable tare weight value for display and
logging purposes
Belt speed
REAL
DBD032
Current speed [LU/s]
Belt speed in %
INT
DBW036
Belt speed in % related to the nominal speed
Belt load in %
INT
DBW038
Belt load in relation with the nominal belt load
Nominal belt load
REAL
DBD040
Nominal belt load [WU/LU] calculated from
nominal flowrate and nominal speed
Belt load
REAL
DBD044
Current belt load [WU/LU]
Flowrate 1
REAL
DBD048
Flowrate 1 [WU./s]
Flowrate 2
REAL
DBD052
Flowrate 2 [WU/h]
Flowrate 3
REAL
DBD056
Flowrate 3 [LWU/h]
Flowrate in %
INT
DBW060
In reference to the nominal flowrate
Operating hours counter
INT DBW062
(is not reset, begins after overflow at 0)
Pulse counter value
DINT
DBD064
Pulse counter value in reference to the set
measuring time
68
Table 5-13
Allocation of DR 30
5.15.1 DR 30 - NAWI Status Bits
Bit No.
Name
Range of Values / Meaning
Reference
0
WR1
Weight within weighing range 1
1
WR2
Weight is in weighing range 2
2
WR3
Weight is in weighing range 3
3
Limit 1
Limit value 1 activated
4
Limit 2
Limit value 2 activated
5
Limit 3
Limit value 3 activated
6
Tared (NET)
Set if the scale is tared
7
Preset Tare
Set if the scale was tared with tare input
8
Max+9e
Set if maximum load is exceeded by 9 e
9
¼d zero
Set if the weight does not exceed ¼ d
10
Waiting for stand-still
Set if the scale waits for a stand-still after the weighing
start.
11
Standstill
Standstill exists
12
Scale adjusted
Set if the scale is adjusted (calibrated)
13
Error on DI
Set if a command could not be executed on a digital input
14
Simulation active
Set if the weight simulation has been activated
15
Service operation active
Set if service operation has been activated
16
Printing log
The log is being printed.
17
RS232-Print not possible
The log cannot be printed.
18
MMC inserted
The MMC is in position
19
MMC ready
The MMC is formatted and ready for recording
20
MMC-trace ready
The MMC is ready for the trace function
21
MMC-log ready
The MMC is ready for logging
22
Trace active
The trace function is activated
5-74
SIWAREX FTC
Summary of Contents for SIWAREX FTC
Page 1: ...SIWAREX FTC Device Manual Status 10 2010 Module for Belt scale ...
Page 12: ......
Page 134: ...11 Empty 11 122 SIWAREX FTC ...