7.7 Message List Technology Messages
Error
No.
Technology message
- Meaning
Explanation
1-10 MMC
error
1
Card function not executable
MMC defect or non-existent. MMC check
required.
These errors are generated:
If a trace entry should be made to the MMC,
but no formatted MMC is inserted
If the MMC is deleted during a logging/trace
entry.
If the MMC contains data errors that cannot
be restored after insertion.
2
Trace recording aborted since the MMC
is full
The trace recording has been aborted because
there is no more memory available. If recording
to the MMC has been defined, insert a new
MMC. Set the recording method to cyclic
memory before formatting an MCC so that the
oldest data is automatically continuously
overwritten.
If recording to RAM is defined, read the data if
desired and then delete the trace memory. Set
the recording method to cyclic memory if you
want to overwrite the oldest data automatically.
3
Recording aborted since the parameters
have been changed
Trace recording has been aborted because the
recording device parameters have been
changed during the recording process.
4
logging not possible since the MMC is
full
Logging to the MMC cannot be performed
because the memory on the MMC is exhausted.
Use a new MMC.
5
Trace overloaded
The defined cycle for the trace recording cannot
be processed. There may be problems with the
MMC. Use a new MMC.
If the problem still occurs, decrease the
recording cycle of the trace function in DR 7 or
record to the RAM memory (MMC parameter in
DR 7).
11-20 Log output error
11 Error in log
Logging the used text is not possible because a
non-defined code for a variable field has been
defined. Check the log texts in DR 40, 41, 42 or
43.
12 Timeout
print-out
A print-job was not completed within the
monitoring time defined for logging in DR 4.
Check the output device or increase the
monitoring time.