SITRANS WW310
Operating Instructions, 03/2014, A5E33490433-AA
35
Maintenance
10
WARNING
ALWAYS STOP the belt, lock-out, and/or place a "Do Not Energize" tag on the main
disconnect before working on or around the weighfeeder.
10.1
Preventative Maintenance
The maintenance schedule below is recommended to maintain top performance and accuracy of
the system. Weighfeeders mounted in severe weather or dusty conditions may require a more
rigorous maintenance schedule.
Make sure the weigh idler is aligned with the approach and retreat sections for accurate
weighing. Periodic measurement to verify alignment is recommended.
10.1.1
Recommended Preventative Maintenance Schedule
Item
Required Maintenance
Frequency
Comments
Weigh
Section
Blow or brush off any material
building up on load cell area.
Weekly
More frequently in dirty
environments
Belt Tracking
Visually inspect to assure that
conveyer belt remains trained.
Daily
----------
Integrator
controller
Span check
Monthly
Use calibration chain
Calibration
span check
Verify belt zero
Daily, at least
once/week
See Calibration section of
Integrator manual
Bearings
Inspect and lubricate as required
Every 10,000
hours
Use food grade grease (see
notes below)
Belt
Check for holes, wearing, frays, or
other damage
Weekly
Replace as required
Belt side
rollers,
scraper, plow
Check for wear and proper belt
contact
Weekly
Clean and replace as required
Summary of Contents for SITRANS WW310
Page 1: ...SITRANS Weighfeeders SITRANS WW310 Operating Instructions 03 2014 ...
Page 8: ...Introduction 1 1 The Manual SITRANS WW310 6 Operating Instructions 03 2014 A5E33490433 AA ...
Page 14: ...Operation 4 1 Weighfeeders SITRANS WW310 12 Operating Instructions 03 2014 A5E33490433 AA ...
Page 20: ......
Page 22: ...Calibration 6 3 Span SITRANS WW310 20 Operating Instructions 03 2014 A5E33490433 AA ...
Page 24: ...Wiring SITRANS WW310 22 Operating Instructions 03 2014 A5E33490433 AA ...
Page 47: ......