Start Up
8.7 Load cell replacement
SITRANS WW310
30
Operating Instructions, 03/2014, A5E33490433-AA
8.7.2
Installing new load cell
Step 1
Slide the new load cell into position.
Step 2
Install the two bottom load cell mount bolts and tighten them by hand.
The load cell should now be resting against the overload stop.
Step 3
Install the two top/front load cell mount bolts. Tighten them by hand.
Step 4
Start with the bottom load cell mounting bolts, and tighten them to the torque rating specified
with the new load cell. Now tighten the two top/front load cell mounting bolts to the same torque
value.
Step 5
Route the load cell cable to the junction box, and connect the load cell according to the supplied
interwiring diagram.
Repeat for other load cells if necessary
Step 6
Perform a load cell balancing procedure as described in the integrator instruction manual.