Connection
3
3.1
Interconnection
Note
Installation shall be performed only by qualified personnel and in accordance with local
governing regulations.
Flexible conduit is recommended so that excess stress is not applied to the shaft
bearings.
Use appropriate conduit and conduit fittings or cable glands to maintain local approvals.
Connection between the SITRANS WS100 standard unit and the integrator should be
made with three-wire shielded, 0.324 mm² (22 AWG) cable.
To connect the SITRANS WS100 IS unit to the switch isolator, use two-wire shielded
0.324 mm² (22 AWG) cable. Use the same cable to connect the switch isolator to the integrator.
Ground the shield at the integrator end ONLY.
Connection
WS100 standard
Integrator
Red
Speed excitation
White
Speed signal
Black
Speed common
WS100 IS
IS Switch Isolator Terminal
Integrator
Brown
1
Blue
3
7
Speed signal
8
Speed common