SITRANS TH400
Operating Instructions, 06/2010, A5E01018688-02
37
Technical data
10
Input
Measurement rate of the analog-to-digital
conversion
< 50 ms
Resolution of the analog-to-digital conversion
24 Bit
Resistance thermometer and linear resistance input:
Resistance thermometer
Min. value
Max. value
Standard
Pt25 ... Pt1000
-200°C
+850°C
IEC60751/JIS C 1604
NI25 ... Ni1000
-60°C
+250°C
DIN 43760
Cu10 ... Cu1000
-50°C
+200°C
α = 0.00427
Line resistance per sensor cable
Max. 50 Ω
Sensor current
Nominal 0.2 mA
Sensor fault recognition
Sensor break recognition
Yes
Sensor short circuit recognition
Yes
Short circuit recognition
< 15 Ω
Input of resistance-type transmitter
Resistance-type
transmitter
Min. value
Max. value
Resistance-type
transmitter
0 Ω
10 kΩ
Line resistance per sensor cable
Max. 50 Ω
Sensor current
Nominal 0.2 mA
Sensor fault recognition
Sensor break recognition
Yes
Sensor short circuit recognition
Yes
Short circuit recognition
< 15 Ω
Summary of Contents for SITRANS TH400
Page 30: ...Commissioning SITRANS TH400 30 Operating Instructions 06 2010 A5E01018688 02 ...
Page 36: ...Service and maintenance SITRANS TH400 36 Operating Instructions 06 2010 A5E01018688 02 ...
Page 44: ...Technical data SITRANS TH400 44 Operating Instructions 06 2010 A5E01018688 02 ...
Page 46: ...Dimension drawings SITRANS TH400 46 Operating Instructions 06 2010 A5E01018688 02 ...
Page 54: ...Appendix A 3 Technical support SITRANS TH400 54 Operating Instructions 06 2010 A5E01018688 02 ...
Page 60: ...Glossary SITRANS TH400 60 Operating Instructions 06 2010 A5E01018688 02 ...
Page 62: ...Index SITRANS TH400 62 Operating Instructions 06 2010 A5E01018688 02 ...