SITRANS TH/TR/TF
26
A5E32520700-01, 06/2013
7
Technical data
Note
SITRANS TF
For SITRANS TF, please refer to the built
-
in transmitter's specifications (SITRANS TH200, TH300, TH400)
Input
SITRANS TH100
SITRANS TH200/TH300,
TR200/TR300
SITRANS TH400
Interface
1)
●
Standard connection
x
x
x
●
Averaging
x
x
●
Differentiation
x
x
Sensor current
approx. 0,4
mA
≤
0,45 mA
nominal 0,2
mA
Measuring cycle
< 0,7 s
≤
250 ms for 1 sensor with
break monitoring
≤
400 ms
Break monitoring
x
x
Short circuit monitoring
x
x
1)
Fo
r connection diagrams see ConnectionHotspot text
(Page
Resistance thermometers
Table
7-1
Measured variable: Temperature
SITRANS TH100/200/300,
TR200/TR300
(for TH100, only PT100), min. span
10 °C (18 °F)
SITRANS TH400
Range °C (°F)
Range °C (°F)
Input point
According to IEC 60751
●
Pt25
-200 ...
+850 (
-328 ...
+1562)
-200 ...
+850 (
-328 ...
+1562)
●
Pt50
-200 ...
+850 (
-328 ...
+1562)
-200 ...
+850 (
-328 ...
+1562)
●
Pt100
...
Pt200
-200 ...
+850 (
-328 ...
+1562)
-200 ...
+850 (
-328 ...
+1562)
●
Pt500
-200 ...
+850 (
-328 ...
+1562)
-200 ...
+850 (
-328 ...
+1562)
●
Pt1000
-200 ...
+350 (
-328 ...
+662)
-200 ...
+850 (
-328 ...
+1562)
●
Ni25 ... Ni1000
-60 ...
+250 (
-76 ...
+482)
-60 ...
+250 (
-76 ...
+482)
According to JIS
C1604-81
●
Pt25
-200 ...
+649 (
-328 ...
+1200)
-200 ...
+850 (
-328 ...
+1562)
●
Pt50
-200 ...
+649 (
-328 ...
+1200)
-200 ...
+850 (
-328 ...
+1562)
●
Pt100
...
Pt200
-200 ...
+64
9 (-328 ...
+1200)
-200 ...
+850 (
-328 ...
+1562)
●
Pt500
-200 ...
+649 (
-328 ...
+1200)
-200 ...
+850 (
-328 ...
+1562)
●
Pt1000
-200 ...
+350 (
-328 ...
+662)
-200 ...
+850 (
-328 ...
+1562)
●
Cu10 … Cu1000
-50 ...
+200 (
-58 ...
+392)