SITRANS P, DS III series (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434645-01, 08/2011
5
Checking the consignment
1.
Check the packaging and the device for visible damage caused by inappropriate handling during shipping.
2.
Report any claims for damages immediately to the shipping company.
3.
Retain damaged parts for clarification.
4.
Check the scope of delivery by comparing the shipping documents with your order for correctness and completeness.
WARNING
Using a damaged or incomplete device
Danger of explosion in hazardous areas.
● Do not use any damaged or incomplete devices.
Nameplate layout
Nameplate with general information
The nameplate bearing the Order No. and other important information, such as design details and technical data, is on the
side of the enclosure.
F illing
Silik onöl
Mat.: Connec. Diaphr.
V :DC1 0.5-45 V (not intr.s ave ) outp.:4-20 mA
H
Measuring span
Ove rrange limits
Type of protection IP 65
Fab. Nr. N1LN1 1-0 047 11
Tr ansmit ter fo r pressur e
1.4404
2.481 9
7MF4033-1EB1 0-1D A1
: 0.6 3 - 6 3 bar
: - 1 - 100 bar
Made in Fr ance
0 032
PED:SEP
SITRANS P
D-76181 K arlsr uhe
①
Order number (machine-readable product code)
②
Serial number
Figure 1
Example of a nameplate