DS III input with PMC connection
HART
PROFIBUS PA or Foundation Fieldbus
0.16 …
16 bar g (2.3
… 232 psi g)
21 bar g
(305 psi g)
32 bar g
(464 psi g)
16 bar g
(232 psi g)
21 bar g
(305 psi g)
32 bar g
(464 psi g)
1)
1 bar g (14.5 psi g) only in PMC Style Standard, not in Minibolt
Absolute pressure input (from the gauge pressure series)
HART
PROFIBUS PA or Foundation Fieldbus
Measured variable
Absolute pressure
Span
Maximum
operating
pressure
MAWP (PS)
Maximum
test
pressure
Measuring
range
Maximum
operating
pressure
Maximum
test pressure
8.3 …
250 mbar a (3
... 100 inH
2
O)
1.5 bar a
(21.8 psi a)
6 bar a
(87 psi a)
250 mbar a
(100 inH
2
O)
1.5 bar a
(21.8 psi a)
6 bar a
(87 psi a)
43 …
1300 mbar a
(17 ...
525 inH
2
O)
2.6 bar a
(37.7 psi a)
10 bar a
(145 psi a)
1.3 bar a
(18.9 psi a)
2.6 bar a
(37.7 psi a)
10 bar a
(145 psi a)
160 …
5000 bar a
(2.32 …
72.5 psi a)
10 bar a
(145 psi a)
30 bar a
(435 psi a)
5 bar a
(72.5 psi a)
10 bar a
(145 psi a)
30 bar a
(435 psi a)
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
DIN 16086)
1 … 30 bar a
(14.5 …
435 psi a)
45 bar a
(653 psi a)
100 bar a
(1450 psi a)
3 bar a
(435 psi a)
45 bar a
(653 psi a)
100 bar a
(1450 psi a)
Absolute pressure input (from the differential pressure series)
HART
PROFIBUS PA or Foundation Fieldbus
Measured variable
Absolute pressure
Span
Maximum
operating pressure
MAWP (PS)
Measuring range
Maximum
operating pressure
8.3 … 250 mbar a (3
… 100 inH
2
O))
32 bar a (464 psi a)
250 mbar a (100
inH
2
O)
32 bar a (464 psi a)
43 … 1300 mbar a
(17 ... 525 inH
2
O)
32 bar a (464 psi a)
1300 mbar a (525
inH
2
O)
32 bar a (464 psi a)
160 … 5000 bar a
(2.32 … 72.5 psi a)
32 bar a (464 psi a)
5 bar a (72.5 psi a) 32 bar a (464 psi a)
1 … 30 bar a
(14.5 … 435 psi a)
160 bar a (2320 psi a) 30 bar a (435 psi a) 160 bar a (2320 psi a)
Span (continuously
adjustable) or measuring
range and max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive)
5.3 … 100 bar a
(76.9 … 1450 psi a)
160 bar a (2320 psi a) 100 bar a
(1450 psi a)
160 bar a (2320 psi a)
Differential pressure and flow rate input
HART
PROFIBUS PA or Foundation Fieldbus
Measured variable
Differential pressure and flow rate
Span
Maximum operating
pressure MAWP (PS)
Measuring range
Maximum operating
pressure
Span (continuously
adjustable) or measuring
range and max. operating
pressure (in accordance
1 … 20 mbar (0.4015
… 8.031 inH
2
O)
32 bar (464 psi)
20 mbar
(8.031 inH
2
O)
32 bar a (464 psi)