Technical data
8.5 Liner selection
43
[µS/cm]
50
40
20
5
30
10
50
300
400
500
[m]
100
200
[ft]
1500
1200
900
150 300
600
Conductivity
of medium
Special cable
Cable length
WARNING
For detection of empty sensor the min. conductivity must always be >50 μS/cm and the
max. length of the electrode cable when remote mounted is 50 meters (164 ft). Special
cable must be used!
For remote MID installations the max. cable length is 3 meters (9.8 ft). For other CT
application standard requirements are applicable.
8.5
Liner selection
Liner
Applications
EPDM
Drinking water applications (not hydrocarbons)
Ebonite
Drinking water applications wastewater applications and
certain chemicals applications
NBR
General purpose. Drinking water, sea waters
8.6
Electrode selection
Electrodes
Hastelloy C
The preferred choice for water and wastewater, chemicals,
food and beverage, and pharmaceutical industries