SITRANS LR200 with mA/HART
168
Operating Instructions, 05/2019, A5E32337676-AE
A.15.3
Horn antennas
The end of the horn should protrude a minimum of 10 mm (0.4”) to avoid interference from
the nozzle.
①
10 mm (0.4")
A.15.4
Threaded rod antenna
1.5” or 2” threaded process connections are available in three thread types: NPT, BSP, and
G.
①
PTFE
②
316 S.S.
③
Max. nozzle height 100 mm (4")
④
Min I.D. 100 mm (4")