
Setup with the integrated HMI
7.5.2 Quick setup level, space, distance
7.5.2
Quick setup level, space, distance
Mode
OPERATION: LEVEL, SPACE, DIST
Sets the mode of operation that determines the output and display:
Setting
Description
LEVEL
Level
SPACE
Space
DIST
Distance
VOL
Volume
VFLOW
Volume flow
1
Distance
2
Space
3
Upper calibration point
4
Transmitter reference point
5
Lower calibration point
6
Level
Figure 7.6
Overview quick setup level, ullage, distance, user-specific
Setting
Description
Reference point
LEVEL
Material height
Lower calibration point (zero point of
the process)
SPACE
Distance from the Upper calibration
point to the material surface
Upper calibration point (full point of the
process)
DIST
Distance to the material surface
Lower calibration point
36
SITRANS LR150
Operating Instructions, 08/2020,
A5E50352155