Connecting
5.4 Connecting the FC410
FC410 with Modbus
40
Operating Instructions, 02/2016, A5E33120874-AC
5.4.2
Cable termination version
A: Prepare the cable by stripping it at both ends.
Image 5-1
Cable end
B: Connect wires within the sensor terminal compartment
1.
Remove the lock screw and remove the lid.
2.
Undo the flexible strap.
3.
Disconnect the sensor connection (white plug) from the electronic.
4.
Loosen the mounting screw using a TX10 Torx driver and remove the electronic from the
housing.
5.
Remove the cap and the ferrule from the cable gland and slide onto the cable.
6.
Push the cable through the open gland and anchor the cable shield and the wires with the
clamp bar.
7.
Remove the terminal block from the electronic.
8.
Connect the wires to the terminals according to the list below.
Terminal number
Description
Wire color (Siemens cable)
1
24 VDC
Orange
2
0 VDC
Yellow
3
B
White
4
A
Blue