Sensor dimension
Unit
Range
DN 80
Mass flow kg/s
0 to +251
Volume flow m
3
/s 0 to +0.249
DN 100
Mass flow kg/s
Volume flow m
3
/s
DN 150
Mass flow kg/s
Volume flow m
3
/s
A.2.5
Zero point adjustment: Sensor dimension dependent default settings (Process
values)
Zero point adjustment
Sensor dimension
Default value
kg/s
Default value
kg/h
Standard deviation limit
DN 15
0.0008
2.88
DN 25
0.0027
9.72
DN 50
0.009
32.4
DN 80
0.04
144
DN 100
0.0832
299.52
DN 150
0.1376
495.36
Offset limit
DN 15
0.012333333
44.4
DN 25
0.056166667
202.2
DN 50
0.140444444
505.6
DN 80
0.368611111
1327
DN 100
0.783
2820
DN 150
1.269
4570
Sensor dimension
Default value
m³/s
Hysteresis
DN 15
0
DN 25
0
DN 50
0
DN 80
0
DN 100
0
DN 150
0
Technical reference
A.2 Sensor dimension dependent default settings
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB
233