Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
120
Hardware Installation Manual, 11/2015, A5E34981613-AC
Status/Alarms:
Makeup
10007 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
8
1
Status/Alarms:
Interface
10008 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
9
1
Status/Alarms:
Zeromatic
10010 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
2
1
Delta Time
30177 4
Real
Analog_In
19 Float
n/a
ADF(Float) 14 1
Delta Time Units
30629 8
String
String_In
48 UINT16
n/a
BD(Byte)
97 8
Analog Input 1
30277 4
Real
Analog_In
20 Float
n/a
ADF(Float) 15 1
AI1 Units
30797 8
String
String_In
52 UINT16
n/a
BD(Byte)
105 8
Analog Input 2
30279 4
Real
Analog_In
21 Float
n/a
ADF(Float) 16 1
AI2 Units
30801 8
String
String_In
56 UINT16
n/a
BD(Byte)
113 8
Analog Input 3
30281 4
Real
Analog_In
22 Float
n/a
ADF(Float) 17 1
AI3 Units
30805 8
String
String_In
60 UINT16
n/a
BD(Byte)
121 8
Analog Input 4
30283 4
Real
Analog_In
23 Float
n/a
ADF(Float) 18 1
AI4 Units
30809 8
String
String_In
64 UINT16
n/a
BD(Byte)
129 8
Chiller Efficiency 1 30211 4
Real
Analog_In
24 Float
n/a
ADF(Float) 19 1
Chiller Efficiency 2 30217 4
Real
Analog_In
25 Float
n/a
ADF(Float) 20 1
Chiller Efficiency 3 30223 4
Real
Analog_In
26 Float
n/a
ADF(Float) 21 1
CE Units
30669 8
String
String_In
68 UINT16
n/a
BD(Byte)
137 8
A.1.25
Profile 24
Profile 24 (FUE1010-5EN02-5.04.05-1RF)
Data Description Modbus
Ethernet/IP
HART
N2
Reg
Bytes Type
Tag Name OS Format CMD VAR
Type
Ad Sz
Site ID
30501
8
String String_In
0
UINT16
n/a
BD(Byte)
1
1
Date: Year
30101
2
Integer Analog_In
0
Float
n/a
ADI(Int)
1
1
Date: Month
30102
2
Integer Analog_In
1
Float
n/a
ADI(Int)
2
1
Date: Day
30103
2
Integer Analog_In
2
Float
n/a
ADI(Int)
3
1
Time: Hour
30104
2
Integer Analog_In
3
Float
n/a
ADI(Int)
4
1
Time: Minute
30105
2
Integer Analog_In
4
Float
n/a
ADI(Int)
5
1
Time: Second
30106
2
Integer Analog_In
5
Float
n/a
ADI(Int)
6
1
Avg Energy Rate 30199
4
Real
Analog_In
6
Float
129 39-27h T ADF(Float)
1
1
Inst.Energy Rate 30193
4
Real
Analog_In
7
Float
n/a
ADF(Float)
2
1
Energy Rate
Units
30653
8
String String_In
4
UINT16 131 39-27h
BD(Byte)
9
8
Energy Total
30205
4
Real
Analog_In
8
Float
129 42-2Ah Q ADF(Float)
3
1
EnergyTotal
Units
30661
8
String String_In
8
UINT16 131 42-2Ah
BD(Byte)
17 8
Inst.Flow Rate
30107
4
Real
Analog_In
9
Float
n/a
ADF(Float)
4
1
Avg Flow Rate
30119
4
Real
Analog_In
10 Float
129 0-00h P
ADF(Float)
5
1
Flow Rate Units 30517
8
String String_In
12 UINT16 131 0-00h
BD(Byte)
25 8
Total
30143
4
Real
Analog_In
11 Float
129 33-21h S ADF(Float)
6
1
Total Units
30557
8
String String_In
16 UINT16 131 33-21h
BD(Byte)
33 8
Supply Temp
30301
4
Real
Analog_In
12 Float
n/a
ADF(Float)
7
1