Note
Electromagnetic compatibility (EMC)
You can use this device in industrial environments, households and small businesses.
For metal enclosures there is an increased electromagnetic compatibility compared to high-
frequency radiation. This protection can be increased by grounding the enclosure.
See also
Note
Improvement of interference immunity
● Lay signal cables separate from cables with voltages > 60 V.
● Use cables with twisted wires.
● Keep device and cables at a distance from strong electromagnetic fields.
● Take account of the conditions for communication specified in the Modbus Communication
● Use shielded cables to guarantee the full specification according to HART/PA/FF/Modbus/
EIA-485/Profibus DP.
4.2
Connecting the FC410
4.2.1
Warnings
WARNING
Improper handling
The sensor connected to this device can be operated with high pressure and corrosive media.
Therefore improper handling of the device can lead to serious injuries and/or considerable
material damage.
● Only use cables with at least the same degree of protection as the sensor to install the
sensor.
It is recommended to use cables supplied by Siemens.
● Siemens supplied cables can be ordered with M12 plug on both ends or without plug.
● To guarantee the IP67 degree of protection, ensure that both ends of the cables are given
equivalent protection from ingress of moisture.
● For further information on Siemens-supplied cables, see Technical data (Page 41).
Connecting
4.2 Connecting the FC410
SITRANS FC410
Compact Operating Instructions, 05/2020, A5E39942309-AB
27