Factory settings
B.3 60 Hz Dimension dependent
MAG 6000 I / MAG 6000 I Ex de transmitter
92
Operating Instructions, 04/2016, A5E02083319-AG
DN
Q
max*
Factory
setting
MAG 5100 W (Order no. 7ME6520) MAG 1100, MAG 1100 F, 5100 W
(Order no. 7ME6580), MAG 3100,
3100 P
unit
mm (inch)
min.
max.
min.
max.
2200 (90)
50000
-
-
3421,195
136847.7
m
3
/h
2400 (96)
55000
-
-
4071.505
162860.1
m
3
/h
2600 (102)
60000
-
-
4778.363
191134.4
m
3
/h
280 (114)
65000
-
-
5541.77
221670.7
m
3
/h
3000 (120)
70000
-
-
6361.726
254469
m
3
/h
* The min. and max. amount values show mathematical values and do not indicate
measurement accuracy
B.3
60 Hz Dimension dependent
60 Hz Dimension dependent factory settings MAG 1100, MAG1100F, MAG 3100, MAG 3100 P and
MAG 5100W with ½" NPT cable glands
DN
Q
max
.
Factory
setting*
MAG 5100 W (Order no. 7ME6520) MAG 1100, MAG 1100 F, 5100 W
(Order no. 7ME6580) MAG 3100,
3100 P
unit
mm (inch)
min.
max.
min.
max.
2 (
1
/
12
)
0.14
-
-
0.01718714
0.6874852
US GPM
3 (
1
/
8
)
0.31
-
-
0.02800984
1.120393
US GPM
6 (
1
/
4
)
1.4
-
-
0.1120394
4.481573
US GPM
10 (
3
/
8
)
4
-
-
0.3112204
12.44881
US GPM
15 (½)
9
-
-
0.7002459
28.0
US GPM
25 (1)
23
441.7865
17671.45
1.945128
77.80509
US GPM
40 (1½)
53
1.130974
45.23893
4.979526
199.181
US GPM
50 (2)
89
6.932434
277.2973
7.78051
311.2203
US GPM
65 (2½)
133
11.00577
440.2305
13.14907
525.9624
US GPM
80 (3)
221
17.62753
705.1008
19.91811
796.7241
US GPM
100(4)
529
27.52745
1101.097
31.12204
1244.881
US GPM
125 (5)
793
44.05714
1762.285
48.62819
1945.127
US GPM
Summary of Contents for SITRANS F MAG 6000 EX DE