Commissioning
6.5 Changing operator menu setup
MAG 6000 I / MAG 6000 I Ex de transmitter
Operating Instructions, 04/2016, A5E02083319-AG
45
Changing decimal point position
1.
Enter the respective totalizer menu.
2.
Use select key
to position cursor below decimal point.
3.
Use change key
to move decimal point to requested position.
Changing units
1.
Use select key
to position cursor below unit.
2.
Press change key
until requested unit is displayed.
6.5
Changing operator menu setup
In the operator menu the menus required for daily operation of the flowmeter are shown. It is
possible to hide and change some of the menus in the operator menu. This is done in the
operator menu setup menu, see operator menu setup diagram below.
Customizing menus in operator menu
To customize the menus in the operator menu perform the following steps:
1.
Press top up key
for 2 sec.
2.
Enter password.
3.
Use forward key or backward key
to reach operator menu.
Changing text in line 1
1.
Press lock/unlock key
to unlock setting.
2.
Use change key
to select desired text.
3.
Press lock/unlock key
to confirm selected text.
Note
If "Text" is selected in line 2, this line functions as a heading for the value shown in line 3.
Otherwise it shows the actual value of the reading selected.
Enabling two readings
1.
Use forward key to reach requested menu.
2.
Press lock/unlock key
to unlock setting.
3.
Use select key
to move cursor to upper line.
4.
Use change key
to select requested reading.
5.
Press lock/unlock key
to confirm selection.
Summary of Contents for SITRANS F MAG 6000 EX DE