Tariff symbol shows actual accounting tariff. In operator menu, tariff value will change to "r" if
information is resettable.
Alarm symbol is active when an alarm is active and shown independently of alarm output
configuration.
Empty pipe symbol indicates an empty pipe condition. To conserve power and prevent false
readings due to exposed measurement electrodes, flow measurement is disabled until a full
pipe is detected and the symbol has disappeared.
Power supply type is automatically detected by meter.
Plug symbol indicates that mains power is supplied.
Battery symbol indicates that battery power is supplied. It also indicates remaining battery
capacity, see Operation menu index 1 (Page 62) for more information.
Bottom part of display shows menu bar.
,QGH[IRUVKRZQPHQXDQG
DFFHSWDEOHYDOXHLQGLFDWLRQ
'HIDXOWRSHUDWRUPHQX
0HWHULQIRUPDWLRQPHQX
6HUYLFHPHQX
'DWDORJJHUPHQX
6WDWLVWLFVPHQXDGYDQFHGYHUVLRQRQO\
7DULIIPHQXDGYDQFHGYHUVLRQRQO\
0HQXEDU
Figure 7-4
Menu bar
The menu bar icons indicate actual selected menu and related index for selected information.
Display overview shows relation between menu, index and information.
Only operator menu ( ) has information and functions that can be reset. During power-up
function battery power can be preset to 100% capacity and time and date can be adjusted -
an "A" in index shows acceptable values. The menu shown in each menu index is the menu
bar.
7.3
Default display information and accessible display menus
Parameter 131 defines the default display information with selection between
● Totalizer 1 (Index 1)
● Totalizer 2 (Index 2)
● Actual flow rate (Index 3, updated with selected measuring frequency)
Operation
7.3 Default display information and accessible display menus
SITRANS MAG 8000
Operating Instructions, 11/2018, A5E03071515-AE