Technical data
11.4 Cable data
71
Batch on relay output
Unidirectional mode (forward flow only)
Hold
Batch
11.4
Cable data
Description
Cable for standard electrode or coil
Electrode cable, double shielded
Cable kit with standard coil cable and electrode cable double
shielded (also available as low noise cable for MAG 1100
sensor )
Technical data
Standard electrode
cable
(electrode/coil)
Special cable
(electrode)
Basic data
No. of conductors
3
3
Sqr. area
1.5 mm
2
0.25 mm
2
Screen
Yes
Double
Color code
Brown, blue, black
Brown, blue, black
Outside color
Grey
Grey
Ext. diameter
7.8 mm
8.1 mm
Conductor
Flexible CU
Flexible CU
Isolation material
PVC
PVC
Ambient temperature
Flexible installation
-5 ... +70°C
(23 ... 158°F)
-5 ... +70°C
(23 ... 158°F)
Non-flexible installtaion
-30 ... +70°C
(-22 ... 158°F)
-30 ... +70°C
(-22 ... 158°F)
Cable parameter
Capacity
161.50 pF/m
N/A
Inductance
0.583 μH/m
N/A
L/R
43.83 þH/Ω
N/A