Functions
7.2 External input
49
7.2
External input
By applying 11 … 30 V DC to terminals 77 and 78, it is possible to perform:
●
Batch control (start, stop, hold/continue)
●
Reset totalizer
●
Force/freeze output
●
Q
max
2 (night)
See external input menu diagram.
Note
Batch settings
Only MAG 6000.
Not available in MAG 5000, MAG 5000 CT and MAG 6000 CT.
Note
Manual cleaning
If the digital input is used for manual cleaning, the relay output also automatically changes to
"cleaning".
7.3
Sensor characteristics
The sensor characteristics menu shows:
●
If a SENSORPROM
®
is installed or not.
●
Suppress error P 40 (SENSORPROM
®
not installed)
●
Sensor size.
●
Calibration factor.
●
Correction factor.
●
Excitation.
See also sensor characteristics menu diagram.
7.4
Reset mode
The reset mode is used for resetting totalizers/counters or for restoring MAG 5000/6000 to
its factory settings.