Version
MAG 3100 P
MAG 3100
MAG 3100 HT
Electrode material
• Hastelloy C276
(PFA: Hastelloy C22)
• AISI 316Ti (1.4571)
• Hastelloy C276
(PFA: Hastelloy C22)
• Platinum/Iridium,
• Titanium
• Tantalum
• AISI 316Ti (1.4571)
• Hastelloy C276
(PFA: Hastelloy C22)
• Platinum/Iridium,
• Titanium
• Tantalum
Grounding Electrode material • PTFE: Hastelloy
• PFA: Hastelloy
Material as measuring electro‐
des
Exceptions - see ordering data
No grounding electrodes
Terminal box (remote version
only)
• Standard fibre glass rein‐
forced polyamide
• Stainless steel AISI 316
(1.4436)
• Standard fibre glass rein‐
forced polyamide
• Stainless steel AISI 316
(1.4436)
• Stainless steel AISI 316
(1.4436)
Cable entries
Remote installation
• 2 x M20
• 2 x ½" NPT
• 2 x M20
• 2 x ½" NPT
• 2 x M20
• 2 x ½" NPT
Compact installation
MAG 5000/MAG 6000:
• 4 x M20
• 4 x ½" NPT
MAG 6000 I:
• 2 x M20 (for supply/
output)
• 2 x ½" NPT
MAG 6000 I Ex de:
• 2 x M20 (for supply/
output)
• 2 x ½" NPT
MAG 5000/MAG 6000:
• 4 x M20
• 4 x ½" NPT
MAG 6000 I:
• 2 x M20 (for supply/
output)
• 2 x ½" NPT
MAG 6000 I Ex de:
• 2 x M20 (for supply/
output)
• 2 x ½" NPT
-
Table 9-8
Certificates and approvals
Version
MAG 3100 P
MAG 3100
MAG 3100 HT
Calibration
Standard production cali‐
bration, calibration report
shipped with sensor
Zero-point, 2 x 25 % and 2 x 90
%
Zero-point, 2 x 25 % and 2 x 90
%
Zero-point, 2 x 25 % and 2 x 90
%
Conforms to
PED (All EN1092-1 flanges con‐
forms to PED – 97/23/EC
1)
CRN
PED (All EN1092-1 flanges con‐
forms to PED - 97/23/EC
1)
CRN
PED (All EN1092-1 flanges con‐
forms to PED - 97/23/EC
1)
CRN
Material certificate EN
10204 3.1
On request
On request
On request
Technical specifications
SITRANS FM MAG 3100
Operating Instructions, 12/2021, A5E03005599-AE
77