IO-Link 3SU14
12.3 Electronic modules for IO-Link
SIRIUS ACT 3SU1 pushbuttons and signaling devices
352
System Manual, 08/2018, A5E03457306020A/RS-AK/010
12.3.3.4
"Active edge” parameter input
"Active edge” parameter
Selection of type of edges to be counted. The following edge types are available for
selection:
●
None
●
Rising edge
●
Falling edge
●
All edges
Settings
Description
Default setting
0
None
Rising edge
1
Rising edge
—
2
Falling edge
—
3
All edges
—
12.3.3.5
"Threshold” parameter input
“Threshold” parameter
Target value with which the actual switch-on duration count is compared. The target value
can be set to between 0 and 4 294 967 295 (0xFFFFFFF [hex]) seconds. This approximately
corresponds to: 0 to 136 years.
Settings
Description
Default setting
1
Threshold: Minimum value
0
4294967295
Threshold: Maximum value
—
Increment: 1 second
12.3.3.6
"Inverting output” parameter
"Inverting output" parameter
Each output can be parameterized as a normal or an inverting output.
Settings
Description
Default setting
0
Inverting output: disabled
disabled
1
Inverting output: enabled
—