IO-Link 3SU14
12.2 Electronic modules for ID key-operated switches
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
333
12.2.5.11
Parameters for IO-Link devices (according to IO-Link communication specification
V1.1)
Parameter "Parameter (write) access"
With the "Parameter (write) access" parameter, you define whether or not all write and read
access parameters can be accessed.
The table below shows the parameter values.
Table 12- 3 "Parameter (write) Access Lock" parameter
Value
Description
Default setting
0
Parameter (write) access: Unlocked
Unlocked
1
Parameter (write) access: disabled
—
"Data Storage” parameter
With the "Data Storage" parameter, you define whether or not the mechanism for data
storage is disabled.
The table below shows the parameter values.
Table 12- 4 "Data Storage Lock" parameter
Value
Description
Default setting
0
Data Storage: Unlocked
Unlocked
1
Data Storage: disabled
—