AS-Interface 3SU14
11.4 AS-Interface modules for base mounting (enclosure mounting)
SIRIUS ACT 3SU1 pushbuttons and signaling devices
258
System Manual, 08/2018, A5E03457306020A/RS-AK/010
11.4
AS-Interface modules for base mounting (enclosure mounting)
With AS-Interface modules, distributed SIRIUS ACT pushbuttons and indicator lights can be
quickly connected to the AS-Interface communication system. The AS-Interface modules for
base mounting are installed in 3SU18 enclosures. On enclosures with raised cover (Article
No.: 3SU180(5)1-1AA00-0AA1) base mounting is not envisaged.
AS-Interface modules with push-in terminal
Slave type
Number of digital inputs
Number of
digital
outputs
Article number
Standard
inputs
Fail-safe inputs
Siemens Industry Mall (
http://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10251009
4 DI / 4 DQ
4
—
4
3SU1400-2EK10-6AA0
1)
4 DI / 3 DQ AB
4
—
3
3SU1400-2EJ10-6AA0
1)
2F-DI
—
2
—
3SU1400-2EA10-6AA0
2)
2F-DI/1LED
—
2
1
for activating
the LED
(LED not
replaceable)
3SU1401-2EE20-6AA0
2)
(red LED)
3SU1401-2EE60-6AA0
2)
(white LED)
1)
Cannot be mounted in enclosure with 1 command point (3SU18.2-0AA00-0AB. / 3SU18.3-0AA00-0AB. / 3SU18.4-
0AA00-0AB. / 3SU18.6-0AA00-0AB.)
2)
Can be mounted in all enclosures with recess for labeling positions