
3SU14 modules
8.1 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
186
System Manual, 08/2018, A5E03457306020A/RS-AK/010
8.1.9
LED modules 24 V for intrinsic safety (front plate mounting)
LED modules for front plate mounting are installed on the rear face of a holder. The LED
modules are approved in accordance with IEC 60079-11 and are used in hazardous zones
1, 2. They comply with the "ib" type of protection for intrinsic safety.
●
[ATEX] II 2G Ex ib IIC T4 Gb
●
Type of protection: ib (= intrinsically safe, Zone 1)
●
Hazardous areas IIC subject to gas explosion (hydrogen)
●
Device category EPL: Gb
●
Temperature class: T4
Input variables compliant with IEC 60079-11:
●
U
i
= 28.8 V DC
●
U
i
= 24.0 V AC
●
I
i
= 0.3 A
●
P
i
= 1.3 W
You will find additional information in Chapters "ATEX for intrinsically safe circuits
(Page 25)", "Holders (Page 213)", "Mounting (Page 199)".
Typical diagram
Operating voltage
Color of the LED
Article number
You can obtain the technical data, as well as parameters of the interfaces, from the product data
sheet and the EC prototype test certificate.
Siemens Industry Mall
http://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10221527
24 V AC/DC
Amber
3SU1401-1BB00-xAA2
Red
3SU1401-1BB20-xAA2
Yellow
3SU1401-1BB30-xAA2
Green
3SU1401-1BB40-xAA2
Blue
3SU1401-1BB50-xAA2
White
3SU1401-1BB60-xAA2
x: 1 = screw terminals
x: 3 = spring-loaded terminals