![Siemens SIRIUS 3RW5 series Equipment Manual Download Page 40](http://html.mh-extra.com/html/siemens/sirius-3rw5-series/sirius-3rw5-series_equipment-manual_1265469040.webp)
4.2
Removing the 3RW5 communication module from the 3RW5 soft
starter
Requirements
• 3RW52, 3RW55 or 3RW55 Failsafe soft starters
• Removed bus connector (Page 51)
• Screwdriver PH1
• Slotted screwdriver with blade width 5.5 to 8 mm
NOTICE
Damage to property due to electrical voltage
Switch off the power to the 3RW5 soft starter before starting work (main and control supply
voltage).
Note
A magnetic screwdriver simplifies disassembly.
Procedure
NOTICE
Damage to property
Ensure that no foreign matter can get into the slot.
Mounting and dismantling
4.2 Removing the 3RW5 communication module from the 3RW5 soft starter
SIRIUS 3RW5 PROFINET communication modules
40
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004