The illustration below shows example procedures for assembling the reversing contactor
assembly 3RA23 size S00 with screw-type connection. Operating instructions 1 to 5 show
how to assemble the contactors using the mechanical interlock and the connecting clips.
Assembling the reversing contactor assembly with screw-type connection - size S00
Table 2- 67 Assembling the reversing contactor assembly with screw-type connection (size S00)
Step
Operating instruction
Figure
1
Pull the adhesive label off the nameplate on
the right-hand side of contactor Q11.
2
Insert the mechanical interlock into the
opening on the right-hand side of the
contactor.
3
Pull the adhesive label off the nameplate on
the left-hand side of contactor Q12.
4
Insert the connecting clips into the openings
on the contactor.
5
Connect contactors Q11 and Q12 together.
6
Attach the wiring modules for connecting
the main and control current paths to the
contactors from above.
7
Attach the wiring modules for connecting
the main current paths to the contactors
from below.
8
Screw the wiring modules tight with a
screwdriver.