43-TV-25-35 GLO Iss.4 Dec 06 UK
167
A5E01001767-04
Section 7: Firmware Options
Firmware Credit System
The credits system is a flexible way of changing the recorder features without having to up-
grade the firmware. Simply purchase a number of credits to cover your current and possibly
future requirements and the recorder is delivered with the credits loaded. The credit value
in each recorder is displayed in the Factory menu.
Select the Options button and by activating and de-activating the options in the credit list,
the recorder will change its functionality. Go from:
Main Menu > Configure > Setup > Edit >
General > Factory > Credits
.
Table 7.1 : Firmware Options
Firmware option
Credit
value
Description
Full Maths* (Note 1)
4
Full Maths - this can handle math expressions that can consist of expressions up to 100-charac-
ters in length.
Full Maths with
Scripting* (Notes 1&4)
6
A powerful multi-line scripting ability available to solve complex state based applications. Eg.
building an application for: “
If
.. X happens, then Y will happen,
else
.. Z will occur.
Events (Note 3)
6
Events are certain conditions or operations that can be set up and logged according to the time
and date of an occurrence. Subsequently events can be reviewed or displayed on a graph.
Events can produce the following actions: Mark on Chart, Start/stop Logging, start/stop/reset
Totalisers, Acknowledge alarms, Set/clear Relay, Screen change, Print Screen, Email and Reset
max/mins.
Fast Scanning mode
(Note 4)
5
For fast processes, the scan rate and recording of the data can be set for up to 50 times per sec-
ond (20ms) for up to 8 inputs for the SIREC D300 and 16 inputs for the SIREC D400.
Totalisers/
Sterilisation
calculation
(Note 1)
4
Each pen can be associated with a totaliser. Using extra pens, the totalised values can be dis-
played and recorded; multiple totals can be calculated out of the same variable (weekly, monthly,
etc.). The totaliser function can handle Fo and Po sterilisation calculation.
Custom Screens (Note 2)
4
Import custom built screens that have been created in Screen Designer.
Health Watch/
Maintenance
2
The recorder keeps track of important “life actions” for improved diagnostics and preventative
maintenance notification. Including Power cycles, Last powered up, Total On time, Total Off time,
Longest off time, Battery life left, Backlight life left at 100% brightness, Compact Flash insertions,
Hi/Lo CJC value (Hi & Lo temps), Analogue In last factory/user cal, Relay operations.
Print Support
2
Enables the printer option to print text from various screens using a standard PCL (Printer Com-
mand Language) printer, connected to the USB port or to the network
Batch
3
The Batch function allows the user to segment portions of data for further analysis. Batch controls
include Start, Stop, Pause, for viewing, Resume and Abort.
Counters
3
User Counters can be set up and used as a part of the Events system to count an occurrence.
Other counters are available depending on hardware availability. Eg. Alarm, Event, Digital Input,
Relay Output and Pulse counters.
Groups
2
Groups of Pens can be specified and named with a Group name or number.
Remote Viewer/Remote
Control Tool
3
Extends the user interface of the recorder onto the desktop PC. Providing full remote control of
the recorder launched from a web browser.
3
Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent
as a part of an Event occurring, such as: Alarms - In/Out/Ack , Totaliser – Start, Stop or Reset,
Digital Inputs – On, Off or State change, TC Burnout – on a specific Analogue Input channel,
Scheduled Events – Once, Interval, Specific days, Month End.
Summary of Contents for SIREC D200
Page 2: ......
Page 176: ...170 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 Firmware Credit System ...
Page 222: ...216 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 238: ...232 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 258: ...252 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 270: ...264 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 274: ...268 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 Modbus Function Codes ...
Page 284: ...278 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 285: ......