A Appendix
398
7UM61 Manual
C53000-G1176-C127-3
4556
External trip 2: General picked up
(Ext 2 picked up)
External Trips
AM
*
ON
OFF
*
LED
BO
51
156
2
Yes
4557
External trip 2: General TRIP (Ext
2 Gen.TRP)
External Trips
AM
*
ON
*
LED
BO
51
157
2
Yes
4563
>BLOCK external trip 3 (>BLOCK
Ext 3)
External Trips
EM
*
*
*
LED BI
BO
4566
>Trigger external trip 3 (>Ext trip
3)
External Trips
EM
ON
OFF
*
*
LED BI
BO
51
166
1
Yes
4571
External trip 3 is switched OFF
(Ext 3 OFF)
External Trips
AM
ON
OFF
*
*
LED
BO
51
171
1
Yes
4572
External trip 3 is BLOCKED (Ext
3 BLOCKED)
External Trips
AM
ON
OFF
ON
OFF
*
LED
BO
51
172
1
Yes
4573
External trip 3 is ACTIVE (Ext 3
ACTIVE)
External Trips
AM
ON
OFF
*
*
LED
BO
51
173
1
Yes
4576
External trip 3: General picked up
(Ext 3 picked up)
External Trips
AM
*
ON
OFF
*
LED
BO
51
176
2
Yes
4577
External trip 3: General TRIP (Ext
3 Gen.TRP)
External Trips
AM
*
ON
*
LED
BO
51
177
2
Yes
4583
>BLOCK external trip 4 (>BLOCK
Ext 4)
External Trips
EM
*
*
*
LED BI
BO
4586
>Trigger external trip 4 (>Ext trip
4)
External Trips
EM
ON
OFF
*
*
LED BI
BO
51
186
1
Yes
4591
External trip 4 is switched OFF
(Ext 4 OFF)
External Trips
AM
ON
OFF
*
*
LED
BO
51
191
1
Yes
4592
External trip 4 is BLOCKED (Ext
4 BLOCKED)
External Trips
AM
ON
OFF
ON
OFF
*
LED
BO
51
192
1
Yes
4593
External trip 4 is ACTIVE (Ext 4
ACTIVE)
External Trips
AM
ON
OFF
*
*
LED
BO
51
193
1
Yes
4596
External trip 4: General picked up
(Ext 4 picked up)
External Trips
AM
*
ON
OFF
*
LED
BO
51
196
2
Yes
4597
External trip 4: General TRIP (Ext
4 Gen.TRP)
External Trips
AM
*
ON
*
LED
BO
51
197
2
Yes
4822
>BLOCK Restart inhibit motor
(>BLK Re. Inhib.)
Restart Motor
EM
*
*
*
LED BI
BO
4823
>Emergency start rotor (>Emer.
Start
Θ
R)
Restart Motor
EM
ON
OFF
*
*
LED BI
BO
168
51
1
Yes
4824
Restart inhibit motor is switched
OFF (Re. Inhibit OFF)
Restart Motor
AM
ON
OFF
*
*
LED
BO
168
52
1
Yes
4825
Restart inhibit motor is
BLOCKED (Re. Inhibit BLK)
Restart Motor
AM
ON
OFF
*
*
LED
BO
168
53
1
Yes
4826
Restart inhibit motor is ACTIVE
(Re. Inhibit ACT)
Restart Motor
AM
ON
OFF
*
*
LED
BO
168
54
1
Yes
4827
Restart inhibit motor TRIP (Re.
Inhib. TRIP)
Restart Motor
AM
ON
*
*
LED
BO
168
55
1
Yes
4828
>Reset thermal memory rotor
(>RM th.rep.
Θ
R)
Restart Motor
EM
ON
OFF
*
*
LED BI
BO
4829
Reset thermal memory rotor (RM
th.rep.
Θ
R)
Restart Motor
AM
ON
OFF
*
*
LED
BO
168
50
1
Yes
4830
Alarm restart inhibit motor (Re. In-
hib.ALARM)
Restart Motor
AM
ON
OFF
*
*
LED
BO
5002
Suitable measured quantities
present (Operat. Cond.)
P.System Data 1
AM
ON
OFF
*
*
LED
BO
71
2
1
Yes
5010
>BLOCK fuse failure monitor
(>FFM BLOCK)
Measurem.Superv
EM
ON
OFF
ON
OFF
*
LED BI
BO
71
7
1
Yes
5011
>FFM extern undervoltage
(>FFM U< extern)
Measurem.Superv
EM
ON
OFF
*
*
LED BI
BO
71
8
1
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
E
ven
t Lo
g
O
N
/O
F
F
Tr
ip
(F
au
lt)
L
o
g
ON/O
F
F
G
rou
nd F
a
u
lt Lo
g O
N
/O
F
F
Ma
rk
ed
in
Os
cill.
Rec
o
rd
LED
B
ina
ry
Inpu
t
Fu
nc
ti
o
n
K
e
y
Re
la
y
C
h
at
ter
S
u
pp
ress
ion
Ty
p
e
In
fo
rma
ti
o
n
N
u
m
b
er
Da
ta
Un
it
Gen
er
al In
te
rr
o
g
ati
o
n
www
. ElectricalPartManuals