No.
Information
Type of
Informa-
tion
Comments
125
Chatter ON
OUT
Chatter ON
140
Error Sum Alarm
OUT
Error with a summary alarm
144
Error 5V
OUT
Error 5V
145
Error 0V
OUT
Error 0V
146
Error -5V
OUT
Error -5V
147
Error PwrSupply
OUT
Error Power Supply
160
Alarm Sum Event
OUT
Alarm Summary Event
177
Fail Battery
OUT
Failure: Battery empty
178
I/O-Board error
OUT
I/O-Board Error
181
Error A/D-conv.
OUT
Error: A/D converter
183
Error Board 1
OUT
Error Board 1
184
Error Board 2
OUT
Error Board 2
185
Error Board 3
OUT
Error Board 3
186
Error Board 4
OUT
Error Board 4
187
Error Board 5
OUT
Error Board 5
188
Error Board 6
OUT
Error Board 6
189
Error Board 7
OUT
Error Board 7
191
Error Offset
OUT
Error: Offset
192
Error1A/5Awrong
OUT
Error:1A/5Ajumper different from setting
193
Alarm NO calibr
OUT
Alarm: NO calibration data available
194
Error neutralCT
OUT
Error: Neutral CT different from MLFB
220
CT Ph wrong
OUT
Error: Range CT Ph wrong
301
Pow.Sys.Flt.
OUT
Power System fault
302
Fault Event
OUT
Fault Event
303
sens Gnd flt
OUT
sensitive Ground fault
320
Warn Mem. Data
OUT
Warn: Limit of Memory Data exceeded
321
Warn Mem. Para.
OUT
Warn: Limit of Memory Parameter exceeded
322
Warn Mem. Oper.
OUT
Warn: Limit of Memory Operation exceeded
323
Warn Mem. New
OUT
Warn: Limit of Memory New exceeded
335
>GOOSE-Stop
SP
>GOOSE-Stop
502
Relay Drop Out
SP
Relay Drop Out
510
Relay CLOSE
SP
General CLOSE of relay
545
PU Time
VI
Time from Pickup to drop out
546
TRIP Time
VI
Time from Pickup to TRIP
17565
>Blk.offset s.
SP
>Blocking of the offset supervision
17566
Dist.CFC Src
VI
Disturbance CFC Source
Power System Data 1
Description
The device requires certain basic data regarding the protected equipment so that the device can adapt to its
desired application. These may be, for instance, nominal power system and transformer data, measured quan-
tity polarities and their physical connections, breaker properties (where applicable) etc. There are also certain
parameters that are common to all functions, i.e. not associated with a specific protection, control or moni-
toring function. The following section discusses these parameters.
2.1.3
2.1.3.1
Functions
2.1 General
40
SIPROTEC 4, 7SJ62/64, Manual
C53000-G1140-C207-8, Edition 08.2016
Summary of Contents for SIPROTEC 4
Page 8: ...8 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...
Page 18: ...18 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...
Page 30: ...30 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...
Page 540: ...540 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...
Page 594: ...594 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...
Page 720: ...720 SIPROTEC 4 7SJ62 64 Manual C53000 G1140 C207 8 Edition 08 2016 ...