![Siemens SIPLUS ECC8000 Operating Instructions Manual Download Page 11](http://html.mh-extra.com/html/siemens/siplus-ecc8000/siplus-ecc8000_operating-instructions-manual_1265438011.webp)
Description
3.4 Diagnostics on CM-100
SYS-101A
Operating Instructions, 05/2011, A5E03431563F-01
11
Tasks of the individual components
SYS-101A component
Task
SIPLUS ECC1000 CM-100
charging controller
Controlling the charging procedure of electric vehicles
Communication with the electric vehicle according to
IEC 61851
Main contactor
Connection and disconnection of power outlet to charging
socket
Circuit breaker
The miniature circuit breaker protects the cable against
overload and short-circuit. (It must always be provided at the
start of a cable)
Input/output terminals
X1: Infeed of power supply
X2: Power outlet
X4: Potential distribution
Residual-current circuit-breaker
(RCCB)
Residual current operated circuit breaker to provide
protection for persons and property and against fire, as well
as additional protection for direct contact.
Residual current operated circuit breakers of type A
measure AC residual currents and pulsating direct currents.
Circuit breaker
The circuit breaker protects the charging outlet against
overload and short-circuit.
3.4
Diagnostics on CM-100
LED display
The CM-100 has a 3-color LED for displaying operating states and fault conditions.
The LED can be lit in green, orange, or red.
Summary of Contents for SIPLUS ECC8000
Page 4: ...Table of contents SYS 101A 4 Operating Instructions 05 2011 A5E03431563F 01 ...
Page 8: ...Safety instructions SYS 101A 8 Operating Instructions 05 2011 A5E03431563F 01 ...
Page 18: ...Installation SYS 101A 18 Operating Instructions 05 2011 A5E03431563F 01 ...
Page 24: ...Maintenance and repair SYS 101A 24 Operating Instructions 05 2011 A5E03431563F 01 ...
Page 26: ...Dimensional drawings SYS 101A 26 Operating Instructions 05 2011 A5E03431563F 01 ...