Configuring the system
2.4 PCU 50.3 with SITOP UPS module
PCU-Basesoftware (IM8)
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
51
2.4.3
Configuration for exiting the HMI
HMI monitoring
Exiting of the HMI advanced is monitored by a separate application, hmiexit.exe. This
application is started implicitly via the shutdown.bat batch file. In case of error, the
application forces the operating system to shut down. An error occurs if the HMI cannot be
exited within the configured delay.
Optionally, the parameters below can be set for hmiexit in file:
E:\SITOP\hmiexit.ini.
[Actions]
#Waiting time in seconds for closing HMI Advanced applications
Wait = 120
# Action on expiration of the waiting time
ForceShutdown = True
These default settings only need to be changed if it takes longer than 120 seconds to exit the
HMI applications in an OEM installation. This configuration is not usually changed.
Configuring the "EXIT" softkey
During production, the option to shut down the HMI via the "EXIT" softkey in the operating
area menu should be disabled, as this function cannot be synchronized with the UPS
module.
The "EXIT" softkey is disabled by entering ExitButton=False in the regie.ini file.
Hibernate
The operating system’s hibernate mode is suspended when operating the UPS, as the USB
interface always has to be active for the UPS module.
Note
More information can be found in the product descriptions with the corresponding order
number.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...