"Custom" operating area
5.3 Defining the start dialog
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
5-3
Activation by keys
● Hotkey
The "Custom" hotkey on the OP 010 and OP 010C always activates this operating area
(default setting). Other additional configurations are possible.
● Horizontal softkey
Activation via the horizontal softkey 4 in the 1st expanded menu is the default setting.
The softkey assignment can be changed in HMI Advanced; in HMI Embedded sl, this is
done with the help of the Software Configuration Kit (SCK).
Behavior during operating area change
When you change from the "Custom" operating area to another operating area and back
again, the window that was active when you closed the "Custom" operating area reappears
the next time you open it.
5.3
5.3
Defining the start dialog
Overview
The inputs in the CUSTOM.INI file are used to define the start dialog and those in the
RE_xx.INI file for the operating area name in HMI Advanced.
● Dialog header
A text with the dialog header can be entered in this section [Header]. This can be in the
form of either text or an alarm text number, which will make the header language-
dependent:
[Header]
Text="XY special functions"
Text=$80XXX
Default setting:
Text = "Custom"
● Picture in start dialog
In the [Picture] section, it is possible to enter a path to a picture that is displayed at the
start of the application:
[Picture]
Picture=\directory\bild.bmp
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...