List of the INI Files
A.4 DG.INI
HMI Advanced (IM4)
278
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
A.4
DG.INI
Overview
In the operator area "Diagnostics", the access to individual softkeys can be individually set
by entering the protection level.
Enter the required protection level in the DG.INI file under [ACCESSLEVEL]:
[ACCESSLEVEL]
ALARMS=7
; Alarms
SERVICE=7
; Service displays
COMMUNIC-LOG=3
; Communications log
PLC=3
; PLC status
PLC-CHANGE=2
; PLC status: SK "Change Value" (change)
; SK "Reset Value" (undo the change)
; SK "Commit Value" (accept the change)
; interlocked using the manufacturer's
password
REMOTE-DIAGNOSIS=4
; Remote diagnostics
FILE=7
; File functions
RUN-LOG=7
; Softkey "Action log" interlocked using the
user password