Diagnostics and service
5.5 Service displays
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
151
5.5.2
Displaying system resources
Function
The system resources for the NCU are displayed in the dialog "NC utilization":
●
The net and overall runtime of the position controller, the interpolator and the pre-run in
milli-seconds
●
NCU load level as a percentage
●
Buffer filling level as a percentage
The display update is stopped using the "Stop" softkey, the displayed values are updated
again with the "Start" softkey.
5.5.3
Output of configuration data
Function
The configuration data of a machine (HMI version, NCU version, axis configuration, drive
configuration, bus parameters, active bus nodes) can be written into a file and subsequently
read out or printed.
Configuration data is output in 2 stages:
●
Creation of the configuration data file CONFIGURATION_DATA in the "Diagnostics"
operating area by pressing the "Config. data" softkey.
●
Read-out of the CONFIGURATION_DATA file in the “Services” operating area. To do
this, the configuration file CONFIGURATION_DATA is generated.
Procedure:
1.
Select the menu "Service displays".
2.
The horizontal softkey bar changes
3.
Press the "Config. data" softkey.
The system gathers the configuration data, writes it into the file CFGDAT.TXT and
displays it. The path and name of the file are output in the info line.
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...