Parameterizing machine data
3.2 Parameterizing the control using machine data
HMI Advanced (IM4)
100
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Example:
Program
WCS display
SZS display
N110 X100
N110 X100
N120 X0
N130 $P_PFRAME=CTRANS(X,10)
N140 X100
N150 ...
100
0
0
100
100
0
0
110
Note
To set the actual-value display: see the machine manufacturer's information.
3.2.3
Changing the access level for the "Basis WO" softkey
Parameters operating area
MD 9247: $MM_USER_CLASS_BASE_ZERO_OFF_PA can be used to set the access level
from which the "Base WO" softkey is displayed in the "Work offset" window in the
"Parameters" operating area. At the same time, the basic frames are also displayed or
hidden in the "Work offset" window and in the "Active WO + compensations" window.
Machine operating area
MD 9248: $MM_USER_CLASS_BASE_ZERO_OFF_MA can be set to select the access
level from which "WO base" softkey is displayed in the "Scratching" screen in the Machine
operating area or G500 can be entered in the work offset field.
3.2.4
Redefining access levels for NC data
Function
The preset access levels can be modified in the definition file. For machine data, only lower
access levels than the configured access level are permitted; for setting data, higher levels
are also permitted. The file becomes active when the next _N_INITIAL_INI is read in.
Different access levels are specified for writing or reading (parts program or PLC).
Example:
_N_DEF_DIR/_N_SGUD_DEF
; File for global variables
; $PATH=/_N_DEF_DIR
REDEF $MA_CTRLOUT_SEGMENT_NR APR 7 APW 4 MD 30100
; (APR ... Read access)
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...