7.4.8
SI Safe Cams
In the "SI safe cams" diagnostic screen, the following information about the Safe Cam (SCA)
safety function of the selected drive is displayed:
● Status of the function (SCA)
For the selected drive, indicates whether the "Safe Cam" (SCA) safety function has been
selected, is active and is valid. The actual position is also displayed (actual value on the load
side on the CU).
Inactive
Active
Invalid. Safe referencing was not carried out.
● Status of the enabled cams
For each configured and enabled cam, displays the identifier, the minus and plus positions
- as well as the validity of the cam position.
Cam position is reached and the cam is invalid.
Cam position is reached and the cam is valid. Safe referencing was carried out.
Call
MENU SELECT > Diagnostics > Menu forward key > Safety > Menu forward key >SI cams
Figure 7-13
"SI safe cams" diagnostics screen