Program management
13.14 V24
Milling
Operating Manual, 03/2010, 6FC5398-7CP20-1BA0
529
13.14.2
Setting V24 in the program manager
V24 setting
Meaning
Protocol
The following protocols are supported for transfer via the V24 interface:
RTS/CTS (default setting)
Xon/Xoff
Transfer
It is also possible to use a secure protocol for data transfer (ZMODEM
protocol).
Normal (default setting)
secure
For the selected interface, secure data transfer is set in conjunction
with handshake RTS/CTS.
Baud rate
Transfer rate: Transfer rates of up to 115 kbaud can be selected. The
baud rate that can be used depends on the connected device, the
cable length and the general electrical conditions.
110
....
19200 (default)
...
115200
Archive format
Punched tape format (default setting)
Binary format (PC format)
V24 settings (details)
Interface
COM1
Parity
Parity bits are used for error detection: The parity bits are added to the
coded characters to make the number of positions set to "1" an uneven
number (uneven parity) or to an even number (even parity).
None (default setting)
Odd
Even
Stop bits
Number of stop bits for asynchronous data transfer.
1 (default)
2
Data bits
Number of data bits for asynchronous data transfer.
5 bits
...
-8 bits (default setting)
XON (hex)
Only for punched tape format
XOFF (hex)
Only for punched tape format
Summary of Contents for SINUMERIK 840D
Page 6: ...Preface Milling 6 Operating Manual 03 2010 6FC5398 7CP20 1BA0 ...
Page 50: ...Introduction 1 4 User interface Milling 50 Operating Manual 03 2010 6FC5398 7CP20 1BA0 ...
Page 600: ...Appendix A 2 Overview Milling 600 Operating Manual 03 2010 6FC5398 7CP20 1BA0 ...
Page 610: ...Index Milling 610 Operating Manual 03 2010 6FC5398 7CP20 1BA0 ...