Procedure
1.
The part program to be edited has been created and you are in the editor.
2.
Press the "Various" softkey.
3.
Press the ">>" and "Adjust to load" softkeys.
The input window "Adjust to load" opens.
Parameter
Description
Unit
Axis
Channel axis name
Axis dynamics
● Default
Adaptation deactivated. The default controller settings are used.
● Adapt
Adaptation activated. The controller settings are adapted to the currently active
load.
Entire load
Currently active load
● Measure:
Travel movements are executed to derive the load.
● Set:
Fixed value for the moment of inertia is applied.
Measurement result
display
Measurement result display
● On
● Off
Display mode
Duration of measurement result display
● autom. 8s
Disappears automatically after 8 s
● NC Start
Acknowledge the display with the <NC-START> key
Moment of inertia
Moment of inertia of the entire load
The value of the most recent measurement can be applied with the softkey "Insert
last result".
kgm
2
Mass
Mass of the entire load (only for linear axes with linear drives)
kg
Programming technology functions (cycles)
10.6 Further cycles and functions
Turning
624
Operating Manual, 06/2019, A5E44903486B AB