Data lists
5.1 Machine data
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
94
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Number
Identifier: $MN_
Description
13010
DRIVE_LOGIC_NR[n]
Logical drive number
13020
DRIVE_INVERTER_CODE[n]
Power section code of drive module
13030
DRIVE_MODULE_TYPE[n]
Module identifier
13040
DRIVE_TYPE[n]
Identifier of drive type
13050
DRIVE_LOGIC_ADDRESS[n]
Logical drive addresses
13060
DRIVE_TELEGRAM_TYPE[n]
Standard message frame type for PROFIBUS DP
13070
DRIVE_FUNCTION_MASK[n]
DP function used
13080
DRIVE_TYPE_DP[n]
Drive type PROFIBUS DP
5.1.3
Channelspecific machine data
Number
Identifier: $MC_
Description
20150
GCODE_RESET_VALUES[n]
Reset G groups
5.1.4
Axis/spindlespecific machine data
Number
Identifier: $MA_
Description
30100
CTRLOUT_SEGMENT_NR[n]
Setpoint assignment: Drive type
30110
CTRLOUT_MODULE_NR[n]
Setpoint assignment: Drive number/module number
30120
CTRLOUT_NR[n]
Setpoint assignment: Setpoint output on drive
module/module
30130
CTRLOUT_TYPE[n]
Output type of setpoint
30134
IS_UNIPOLAR_OUTPUT[n]
Setpoint output is unipolar
30200
NUM_ENCS
Number of encoders
30210
ENC_SEGMENT_NR[n]
Actual-value assignment: Drive type
30220
ENC_MODULE_NR[n]
Actual-value assignment: Drive module
number/measuring circuit number
30230
ENC_INPUT_NR[n]
Actual-value assignment: Input on drive
module/measuring circuit module
30240
ENC_TYPE[n]
Type of actual-value acquisition (position actual value)
30242
ENC_IS_INDEPENDENT
Encoder is independent
30300
IS_ROT_AX
Rotary axis
30350
SIMU_AX_VDI_OUTPUT
Output of axis signals for simulation axes
31000
ENC_IS_LINEAR[n]
Direct measuring system (linear scale)
31010
ENC_GRID_POINT_DIST[n]
Distance between reference marks on linear scales
31020
ENC_RESOL[n]
Encoder pulses per revolution
31030
LEADSCREW_PITCH
Leadscrew pitch
31040
ENC_IS_DIRECT[n]
Encoder is connected directly to the machine
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...