If remote access is active, using these icons you will be informed in the status line as to whether
a remote access is presently active or whether only monitoring is permitted.
Procedure
1.
Select the "Diagnostics" operating area.
2.
Press the "Remote diag." softkey.
The "Remote diagnostics (RCS)" window is opened.
3.
Press the "Change" softkey.
The "Selected in the HMI" is activated.
4.
If you desire remote control, select the entry "Permit remote control".
In order that remote control is possible, the entry "Allow remote operation"
must be specified in the fields "Specified by PLC" and "Selected in HMI".
5.
Enter new values in the group "Behavior for remote access confirmation"
if you wish to change the behavior for confirming remote access.
6.
Press the "OK" softkey.
The settings are accepted and saved.
References
A description of the configuration options can be found in the following reference:
SINUMERIK Operate Commissioning Manual
15.9.2
Permit modem
You can permit remote access to your control via a teleservice adapter IE connected at X127.
Machine manufacturer
Please refer to the machine manufacturer's instructions.
Software option
You need the "Access MyMachine /P2P" option to display the "Allow modem"
softkey.
Alarm, error, and system messages
15.9 Remote diagnostics
Milling
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0