Unloading tool on code carrier
1.
The tool list is opened.
2.
Place the cursor on the tool that you would like to unload from the mag‐
azine and press the "Unload" and "On code carrier" softkeys.
The tool is unloaded and the data of the tool are written to the code carrier.
According to the corresponding setting, the unloaded tool on the code carrier is deleted from
the NC memory after reading out the code carrier.
Deleting tool on code carrier
1.
The tool list is opened.
2.
Position the cursor on the tool on the code carrier that you want to delete.
3.
Press the "Delete tool" and "On code carrier" softkeys.
The tool is unloaded and the data of the tool are written to the code carrier.
The tool is then deleted from the NC memory.
The deletion of the tool can be set differently, i.e. the "On code carrier" softkey is not available.
13.5.9
Managing a tool in a file
If the "Enable tool in/out file" option is activated in the settings for the tool list, an additional
entry is available in the list of favorites.
Figure 13-18
New tool from file in the list of favorites
Tool management
13.5 Tool list
Milling
710
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0